Program
Thursday, June 9
|
|
|
08:00 |
Registration |
|
09:00 |
Opening: Prof. P. Atzeni (dean of the Department), Prof. G. Caliano |
|
09:15 |
Modeling and characterization of CMUT-based galvanic isolation transformers J. Heller, A. Boulmé, D. Alquier, S. Ngo, C. Compère and D. Certon, Université François Rabelais de Tours, France |
Session 1: Characterization Chair: Prof. L. Degertekin |
09:35 |
Capacitance Voltage Characterization of CMUTs: Analytical modelling, simulations and experiments M. T. Borre, S. E. Diederichsen, M. J. G. Mølgaard, M. Engholm, A. Lei, and E. Vilain Thomsen, Technical University of Denmark, Lyngby, Denmark |
|
09:55 |
Measurements and Large-Scale Simulations of CMUT TOBE Array Parasitic Effects C. Ceroici, R. J. Zemp, Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Canada |
|
10:15 |
Nonlinear ultrasound imaging experiments using a CMUT probe A.S. Savoia1, E. Boni2, A. Ramalli2, G. Matrone3, P. Tortoli2, G. Caliano1; 1Dipartimento di Ingegneria, Università degli Studi Roma Tre, Roma; 2Dipartimento di Ingegneria dell’Informazione, Università degli Studi di Firenze, Firenze; 3Dipartimento di Ingegneria Industriale e dell’Informazione, Università degli Studi di Pavia, Pavia, Italy |
|
10:35 |
Coffee break |
|
11:00 |
Vented CMUT Design for Wide Bandwidth Airborne Applications H. K. Oguz, K. Firouzi, N. Apte and P. Khuri-Yakub; Department of Electrical Engineering Stanford University Stanford, USA |
Session 2: Fabrication I Chair: Prof. G. Caliano |
11:20 |
Fabrication of CMUTs using a boron etch-stop method S. E. Diederichsen, F. Sandborg-Olsen, M. Engholm, K. Christiansen, A. Lei, J. A. Jensen, and E. V. Thomsen, Technical University of Denmark, Lyngby, Denmark |
|
11:40 |
Isolated Isolation Posts for Double-SOI Wafer-Bonded CMUTs B. Greenlay, C. Ceroici, and R. Zemp, Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Canada |
|
12:00 |
Modelling, simulation and experiment of both uniform and stepped thickness cMUT cells S.P. Mao1,2, V. Rochus1, B. Nauwelaers2, G. Brondani Torri1, H.A.C. Tilmans1 and X. Rottenberg1; 1Imec, Belgium; 2Department of Electrical Engineering, KU Leuven, Belgium |
|
12:30 |
Lunch |
|
13:30 |
Front End System Development for CMUT-on-CMOS Based MRI Compatible Intracardiac Echocardiography (ICE) Catheters M. W. Rashid1, T. Carpenter2, G. Jung1, C. Tekes2, D. M. J. Cowell3, S. Freear3, M. Ghovanloo1, O. Kocaturk4, R.J. Lederman4, F. L. Degertekin1,2 1School of Electrical & Computer Engineering, Georgia Institute of Technology; 2G.W. Woodruff School of Mechanical Engineering, Atlanta, GA, USA; 3School of Electronic & Electrical Engineering, University of Leeds, Leeds, West Yorkshire, UK; 4National Heart, Lung and Blood Institute (NHLBI), Bethesda, MD, USA |
Session 3: Application I Chair: Prof. B. T. Khuri-Yakub |
13:50 |
A Row-Column–Addressed 2-D CMUT Probe: Transducer Characterization and Imaging Performance M. Engholm, H. Bouzari, J. A. Jensen, and E. V. Thomsen, Technical University of Denmark, Lyngby, Denmark |
|
14:10 |
Back-End-Of-Line Integration Technology of Capacitive Micromachined Ultrasonic Transducers (CMUT) S. Koch, J. Amelung, L. Elsäßer, M. Kircher, A. Weder, M. Pietzsch, M. Müller; Fraunhofer Institute for Photonic Microsystems (IPMS), Dresden, Germany |
|
14:30 |
A bimodal imaging platform for the diagnosis of early arthritis based on cMUT technology N. Sénégond1, W. Bost2, An Nguyen Dinh1 and M. Fournelle2, 1Vermon S.A, Tours, France; 2Fraunhofer IBMT, St. Inberg, Germany |
|
14:50 |
Coffee break |
|
15:30 |
Optimisation of the LOCOS process for high frequency applications for chemical and biological sensing M. J. G. Mølgaard, J. M. F. Hansen, and E. V. Thomsen, Technical University of Denmark, Lyngby, Denmark |
Session 4: Fabrication II Chair: Dr. J. F. Gelly |
15:50 |
High Frequency CMUT Ring Arrays for Intravascular HIFU: Fabrication and Experimental Results R.B. Roy1, O. Farhanieh1, A.S. Ergun2, A. Bozkurt1, 1Acoustics Group, Sabanci University, Istanbul; 2Department of Electrical and Electronics Engineering of Tobb University of Economic and Technology, Ankara, Turkey |
|
16:10 |
Porous silicon as backing material for capacitive micromachined ultrasonic transducers J. Lascaud, A. Boulmé, D. Gross, E. Bahette, T. Defforge, D.Alquier, G. Gautier and D. Certon, Université François Rabelais de Tours, CNRS, CEA, INSA-CVL, GREMAN Tours, France |
|
16:30 |
CMUT efficiency for HIFU applications D. Gross1, A. N’Djin2, A. Boulmé1, C. Bawiec2, N. Sénégond3 and D. Certon1, 1Université François Rabelais de Tours, Tours, France; 2LabTau, Inserm Lyon, France; 3Vermon S.A., Tours, France |
|
16:50 |
Sponsors presentations: Lyncée Tec, Polytec, PZFlex, Vermon |
|
17:10 |
End of 1st day presentations |
|
19:30 |
Reserved bus departure from the University stop Social dinner: “Terrazza degli Aranci” Rome Cavalieri Hilton Hotel Reserved bus departure to the University stop End of day one |
|
20:00 |
||
23:00 |
||
23.30 |
Friday, June 10
|
|
|
|
2nd day of presentations |
|
09:15 |
Simulating MUT Array Performance Using Time Domain Finite Element Analysis A. Tweedie1, G. Harvey2 and R. L. O’Leary3, 1PZFlex Glasgow, UK; 2PZFlex Cupertino, USA; 3Centre for Ultrasonic Engineering, University of Strathclyde, Glasgow, UK |
Session 5: Modelling II Chair: Prof. N. Lamberti |
09:35 |
Efficient broadband simulation of fluid-structure coupling for large membrane-type MUT arrays B. Shieh, K. Sabra, F. L. Degertekin, G. W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta (USA) |
|
09:55 |
Squeeze film damping in CMUTs with air-filled cavities A. T. Galisultanov, P. Le Moal, V. Walter, G. Bourbon, Department of Applied Mechanics, FEMTO-ST Institute, Besançon, France |
|
10:15 |
Two Sided CMUT H.Köymen and A.Atalar, Bilkent University, Electrical and Electronics Engineering Department, Ankara, Turkey |
|
10:35 |
Coffee break |
|
11:00 |
HIFU Characterization and feasibility: Planar Capacitive Micromachined Ultrasound Transducer (CMUT) probe with 64-element annular array and a linear imaging array for UltraSound-guided High-Intensity Focused Ultrasound (USgHIFU) C. Bawiec1, W.A. N'Djin1, G. Bouchoux1, N. Sénégond2, N. Guillen3, J.Y. Chapelon1, 1Inserm, LabTau, Lyon; 2Université Lyon 1, Lyon; 3Vermon, Tours, France |
Session 6: Application II Chair: Prof. P. Tortoli |
11:20 |
Combined CMUT Array Simulations Using Cadence Spectre I. Köymen, S. Güler, A. Atalar, H. Köymen, Department of Electrical and Electronic Engineering, Bilkent University Ankara, Turkey |
|
11:40 |
cMUT vs Piezocomposite transducer arrays : acoustic pattern and impact on photoacoustic image reconstruction M. Flesch1,2, C. Meynier1, O. Warshavski1, N. Senegond2, A. Nguyen-Dinh1, N. Felix1, 1Vermon, Tours; 2Institut Langevin, Paris, France |
|
12:00 |
Dual Hybrid Ultrasound Transducers T. Manh1, L. Hoff1, T. F. Johanssen2, T. Eggen3, F. Lanteri4 and J.F. Gelly4, 1Department of Micro- and Nano Systems Technology, University College of Southeast Norway, Norway; 2Department of Acoustics, SINTEF ICT, Norway; 3GE Vingmed Ultrasound AS, Norway; 4GE Parallel Design SAS, France |
|
12:30 |
Lunch |
|
14:00 |
MUT 2016 Best Presentation Award |
|
14:15 |
Invitation to MUT 2017 |
|
14:30 |
Panel discussion and closing remarks |
|
15:00 |
Reserved bus departure from the University stop for “Ostia Antica” excavations tour. |
|
19:30 |
Reserved bus departure to University stop |
|
20:00 |
End |
Download here the presentations (.rar file, password protected)